Free shipping all over in USA, Now Bill To Insurance option available. Bill to Insurance
FreeStyle Libre 3 Reader Error Messages
admin October 30, 2024 No Comments

The FreeStyle Libre 3 system is created to be user-friendly when monitoring the blood glucose levels. Like any other device, though, it has a possibility of running into errors that may cause some interference in its use. This article details some of the Freestyle libre 3 reader error messages, together with possible explanations and action that may help solve these issues. With knowledge of these flaws and solutions to them, it’s guaranteed that any person would have a system operating smoothly in monitoring situations for an appropriate health handling process.

Common problems with FreeStyle Libre 3 Reader

Some of the common problems and Freestyle libre 3 reader error messages that might occur with libre 3 reader are discussed below

problem 1

  • The Freestyle libre 3 reader shows error messages

what it may mean

  • It may happen due to Reader battery is too low.
  • Reader is operating outside of its temperature range.

What to do

  • Charge the Reader.
  • Move the Reader to a temperature between 50°F and 113°F and then try to power it on.

Problem 2

  • The Sensor is not be linking with your Reader or there is a problem with your Sensor or Reader

What it may mean

  • The sensor is out of range of the reader.

What to do

  • Keep the Sensor within the range that is 6 metres or 20 feet of the Reader to receive alarms.
  • Keep fit by being in this range.
  • At the top of the home screen, you will see the image of an alarm with a red line through it when your Sensor is not communicating with the Reader.

Problem 3

  • Sensor Already in Use

What it may mean

  • The Sensor may be started by alternative device.

What to do

Both the Reader and App can only be used with a started Sensor. Check your glucose with the device that started it. Or, put on and connect a new Sensor.

Problem 4

  • Incompatible Sensor

What it may mean

  • The FreeStyle Libre 3 Reader and FreeStyle Libre 3 app are for use with the FreeStyle Libre 3 Sensor. Ensure you use the App or Reader compatible with your Sensor. If your Sensor is not supported, you may need to download a different app.

What to do

  • If you’re not sure, tap “Learn more” or call Customer Service.

Problem 5

  • New Sensor Found

What it may mean

  • Scanning of new Sensor may have done prior to Sensor ended.

What to do

  • Your device can function with just one Sensor. If you begin a new Sensor, you will lose the opportunity to use the older Sensor. If you’d prefer to begin with the new Sensor, you may just respond “Yes” and re-scan.

Problem 6

  • The Reader do not initiate a test

What it may mean

  • The reader may outside of its working temperature range.

What to do

  • Move the Reader to a temperature between 50°F and 113°F and then try to power it on.

Problem 7

  • You are not getting alarms.

What it may mean

  • You have enabled Silent Mode through the App.
  • The alarm level may be set lower or higher than you planned.
  • Your Sensor is done.

What to do

  • Make sure your alarm Silent Mode is turned off in settings.
  • Check your alarm settings are suitable.
  • Another alert will occur, if a new low or high glucose episode is starting.
  • Change your Sensor to a new one.

Blood Glucose Error Messages

Some of the error messages associated with Freestyle libre 3 reader are as follows

Error message E-1

  • The temperature is either too hot or too cold for a Reader to operate normally.

What to do

  • Carry the reader to a location where the temperature is within the range.
  • Wait for the reader to acclimate to the new temperature.
  • Repeat the test
  • If the error reappears, contact Customer Service.

Error message E-2

  • It is referring to the reader error
  • What to do

  • Turn off the Reader.
  • Repeat the test.
  • If the error still appears, contact Customer Service.

Error message E-3

  • Blood drop is too small. or Incorrect test procedure. or perhaps an error in the test strip.

What to do

  • Review the test instructions.
  • Repeat the test.
  • If the error repeats, contact Customer Service.

Error Message E-9

When E-9 appears on your reader it is related with reader Error.

What to do

  • Switch off the Reader.
  • Using a new test strip, repeat the test.
  • Contact Customer Service, If the error reappears,

Perform a reader test

If you have any problem with the performance of Reader, you might test Reader. Touch on Settings icon from Home screen and go to System Status -> Reader Test as shown in figure below. Note that the Reader Test will run system internal diagnostics and will check if everything is working-the display, sounds, touch screen.

libre 3 reader error messages

Conclusion

By identifying the various possible errors in association with the Freestyle libre 3 reader error messages, an individual’s perception of usability and reliability with the equipment is impacted dramatically. However, when error arises from the equipment, these general steps of solving each potential error facilitate problem resolution as well as maximizing performance without hassle. Moreover, where issues persist, it will be beneficial at all times to get hold of the customer service desk. Proper care and attention with the FreeStyle Libre 3 system will mean going on with a continuation of having insightful information into your blood glucose levels and one to be in control over his health. To buy freestyle libre 3 reader at an affordable and budget friendly prices, visit our website at Deliver My Meds

Reference

https://freestyleserver.com/payloads/ifu/2023/q3/ART41641-001_rev-A-web.pdf
https://www.freestylelibre.com.au/trouble-shooting?srsltid=AfmBOoqSDtwLJZ2kH8Bg4rLPJ0m-1ZsOCkYi4iwS2QGArPQ-YFSkCY5_

Leave a Reply